V8/TS2060 series Operation Troubles HKFAQ000143

date: 2021/7/8

The data displayed in a trend graph is different from the most recent data in the PLC.

 

<Cause>

The trend graph is not redrawn.

 

<Solution>

The graph data once displayed is not updated unless the redraw command is specified.
To update to the newest data, turn bit 14 or 15 of the control device memory from OFF to ON (leading edge).

 

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
 b  a  0  0  0  Points to Display :  Setting range: 0 - 780 (HEX)

 

  1. Bit 14
    Trend lines are redrawn at the edge (0 → 1) by the specified number of points.
    Drawing is performed over the previous one without clearing the trend graph area.


  2. Bit 15
    Trend lines are redrawn at the edge (0 → 1) by the specified number of points.
    The trend graph area is cleared and the newest trend lines are drawn.

Was this page helpful?

Please cooperate with the questionnaire to make it better.

  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • Communication Error "Timeout"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • "The port cannot be opened."
  • What PLC models can be connected?
  • » 有关产品
  • » 有关销售
  • » 目录请求
  • » RoHS依据

MONITOUCH

产品阵容
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
支持 »
  • 下载
  • 咨询
  • 推荐的相关机器
代理店 »
  • 国外代理店
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved